Recovery Test, Make-Up Air Test, and Test Frequency, here are interview preparation questions and answers tailored to HVAC and cleanroom validation in pharmaceuticals:

✅ PHARMACEUTICAL INTERVIEW QUESTIONS & ANSWERS

📘 TOPIC: RECOVERY TEST, MAKE-UP AIR TEST & TEST FREQUENCY

1. What is a Recovery Test in cleanroom validation?

Answer:

The Recovery Test evaluates how quickly a cleanroom returns to its classified cleanliness level (for temperature or humidity) after a temporary contamination or disturbance. It ensures the effectiveness of non-unidirectional airflow systems.

2. What are the types of recovery tested?

Answer:

1. Humidity Recovery

2. Temperature Recovery

3. Describe the procedure for Humidity Recovery Test.

Answer:

Switch off the AC system.

Increase temperature to 40°C using a hot air blower.

Restart the AC system.

Monitor until humidity returns to design limits.

Record the time taken (as per ISO 14644-3).

4. What is the purpose of the Temperature Recovery Test?

Answer:
To verify how quickly the cleanroom can recover to acceptable temperature levels after an artificial rise in temperature (40°C) and resume temperature control efficiency.

5. What is Makeup Air in HVAC systems?

Answer:
Makeup air is the fresh air supplied into the cleanroom to replace the air lost due to exhaust, leakage, door openings, and maintain positive pressure and cleanroom air quality.

6. How is the Makeup Air CFM calculated?

Answer:
Make Up CFM = Velocity of Makeup Air × Makeup Air Grill Area

7. What is the acceptable pressure differential between cleanroom and adjoining area?

Answer:
The pressure differential should be 0.03 to 0.05 inches of water gauge, equivalent to 7.5 to 13 Pascals, to ensure positive pressurization.

8. Why is positive pressurization important in a cleanroom?

Answer:
Positive pressurization prevents entry of contaminated air from lower classified areas, maintaining cleanliness integrity of the cleanroom.

9. What is the frequency of cleanroom validation tests?

Answer:

Test Frequency

Air Velocity Test Half-yearly
Filter Integrity (PAO) Test Yearly
Non-Viable Particle Count Half-yearly
Recovery Test Half-yearly
Smoke Test / Airflow Pattern Yearly
Viable Count As per SOP (e.g., MU009)
Differential Pressure Monitoring Daily
Temperature & Humidity Monitoring Daily

10. Under what conditions is revalidation of HVAC systems required?

Answer:

Change in facility design or layout

Change in equipment

Major process modification

Impact on air classification

S

Post Views: 18

Related posts:

  1. To get ₹15,000 in your account through the Mother’s Day Salute scheme, you must do these two things by June 12th: Otherwise, the money will not be deposited
  2. HPCL Recruitment For Diploma Engineers- Apply Now
  3. Godrej Walk-In Interview For LGBTQIA+ and PWD
  4. Global Calcium – Walk-In Drive for Quality Control on 14th June’ 2025
Follow US for More ✨Latest Govt. Update's
FollowChannelClick here
FollowChannel

Click here


Follow US for More ✨Latest Pharma Update's
FollowChannelClick here
FollowChannel

Click here


Share
Tweet
Email
Prev Article
Next Article

Related Articles

Good news for women in the state! Soon the Aadabidda Nidhi Scheme will be implemented | Aadabidda Nidhi Scheme Full Details.

Clinical Project Coordinator Job at Labcorp

Clinical Project Coordinator Job at Labcorp

Leave a Reply Cancel Reply

Search

Archives

  • August 2025
  • July 2025
  • June 2025
  • May 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024

Meta

  • Log in

jobaspirants.online

Copyright © 2025 jobaspirants.online

Ad Blocker Detected

Our website is made possible by displaying online advertisements to our visitors. Please consider supporting us by disabling your ad blocker.

Refresh